182 lines
5.9 KiB
Text
182 lines
5.9 KiB
Text
'
|
|
' ScummVM - Graphic Adventure Engine
|
|
'
|
|
' ScummVM is the legal property of its developers, whose names
|
|
' are too numerous to list here. Please refer to the COPYRIGHT
|
|
' file distributed with this source distribution.
|
|
'
|
|
' This program is free software; you can redistribute it and/or
|
|
' modify it under the terms of the GNU General Public License
|
|
' as published by the Free Software Foundation, version 2
|
|
' of the License.
|
|
'
|
|
' This program is distributed in the hope that it will be useful,
|
|
' but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
' MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
' GNU General Public License for more details.
|
|
'
|
|
' You should have received a copy of the GNU General Public License
|
|
' along with this program; if not, write to the Free Software
|
|
' Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA.
|
|
'
|
|
'/
|
|
|
|
''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
|
|
' This script calls the iscc tool to generate a Inno Setup Windows installer for ScummVM
|
|
'
|
|
' It tries to read the Inno Setup installation folder from the registry and then calls the
|
|
' command line script compiler to create the installer.
|
|
'
|
|
' This is called from the postbuild.cmd batch file
|
|
''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
|
|
|
|
'================================================================
|
|
' TODO: Reduce duplication with revision.vbs script
|
|
' (ReadRegistryKey and ParseCommandLine are identical)
|
|
'================================================================
|
|
|
|
Option Explicit
|
|
|
|
Dim FSO : Set FSO = CreateObject("Scripting.FileSystemObject")
|
|
Dim WshShell : Set WshShell = CreateObject("WScript.Shell")
|
|
|
|
' Folders
|
|
Dim rootFolder : rootFolder = ""
|
|
Dim targetFolder : targetFolder = ""
|
|
|
|
' Parse our command line arguments
|
|
If ParseCommandLine() Then
|
|
CreateInstaller()
|
|
End If
|
|
|
|
'////////////////////////////////////////////////////////////////
|
|
'// Installer creation
|
|
'////////////////////////////////////////////////////////////////
|
|
Sub CreateInstaller()
|
|
' Get inno installation folder
|
|
Dim innoPath : innoPath = GetInnoPath()
|
|
If (innoPath = "") Then
|
|
Exit Sub
|
|
End If
|
|
|
|
' Build command line
|
|
Dim commandLine : commandLine = """" & innoPath & "\iscc.exe"" /Qp" & _
|
|
" /O""" & targetFolder & """" & _
|
|
" """ & rootFolder & "\dists\win32\scummvm.iss"""
|
|
|
|
Dim oExec: Set oExec = WshShell.Exec(commandline)
|
|
If Err.Number <> 0 Then
|
|
Wscript.StdErr.WriteLine "Error running iscc.exe!"
|
|
Exit Sub
|
|
End If
|
|
|
|
' Wait till the application is finished ...
|
|
Dim ostdOut : Set oStdOut = oExec.StdOut
|
|
Do While oExec.Status = 0
|
|
If Not ostdOut.AtEndOfStream Then
|
|
Wscript.StdErr.WriteLine ostdOut.ReadAll
|
|
End If
|
|
|
|
WScript.Sleep 100
|
|
Loop
|
|
|
|
If oExec.ExitCode <> 0 Then
|
|
Wscript.StdErr.WriteLine "Error while creating installer!"
|
|
Exit Sub
|
|
End If
|
|
End Sub
|
|
|
|
Function GetInnoPath()
|
|
' Get the directory where Inno Setup (should) reside(s)
|
|
Dim sInno
|
|
|
|
' First, try with 32-bit architecture
|
|
sInno = ReadRegistryKey("HKLM", "SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\Inno Setup 5_is1", "InstallLocation", 32)
|
|
|
|
If sInno = "" Or IsNull(sInno) Then
|
|
' No 32-bit version of Inno Setup installed, try 64-bit version (doesn't hurt on 32-bit machines, it returns nothing or is ignored)
|
|
sInno = ReadRegistryKey("HKLM", "SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\Inno Setup 5_is1", "InstallLocation", 64)
|
|
End If
|
|
|
|
' Check if Inno Setup is present
|
|
If sInno = "" Then
|
|
Wscript.StdErr.WriteLine "Inno Setup not installed!"
|
|
Exit Function
|
|
End If
|
|
|
|
GetInnoPath = sInno
|
|
End Function
|
|
|
|
'////////////////////////////////////////////////////////////////
|
|
'// Utilities
|
|
'////////////////////////////////////////////////////////////////
|
|
Function ParseCommandLine()
|
|
ParseCommandLine = True
|
|
|
|
If Wscript.Arguments.Count <> 2 Then
|
|
Wscript.StdErr.WriteLine "[Error] Invalid number of arguments (was: " & Wscript.Arguments.Count & ", expected: 2)"
|
|
|
|
ParseCommandLine = False
|
|
Exit Function
|
|
End If
|
|
|
|
' Get our arguments
|
|
rootFolder = Wscript.Arguments.Item(0)
|
|
targetFolder = Wscript.Arguments.Item(1)
|
|
|
|
' Check that the folders are valid
|
|
If Not FSO.FolderExists(rootFolder) Then
|
|
Wscript.StdErr.WriteLine "[Error] Invalid root folder (" & rootFolder & ")"
|
|
|
|
ParseCommandLine = False
|
|
Exit Function
|
|
End If
|
|
|
|
If Not FSO.FolderExists(targetFolder) Then
|
|
Wscript.StdErr.WriteLine "[Error] Invalid target folder (" & targetFolder & ")"
|
|
|
|
ParseCommandLine = False
|
|
Exit Function
|
|
End If
|
|
|
|
' Set absolute paths
|
|
rootFolder = FSO.GetAbsolutePathName(rootFolder)
|
|
targetFolder = FSO.GetAbsolutePathName(targetFolder)
|
|
End Function
|
|
|
|
Function ReadRegistryKey(shive, subkey, valuename, architecture)
|
|
Dim hiveKey, objCtx, objLocator, objServices, objReg, Inparams, Outparams
|
|
|
|
' First, get the Registry Provider for the requested architecture
|
|
Set objCtx = CreateObject("WbemScripting.SWbemNamedValueSet")
|
|
objCtx.Add "__ProviderArchitecture", architecture ' Must be 64 of 32
|
|
Set objLocator = CreateObject("Wbemscripting.SWbemLocator")
|
|
Set objServices = objLocator.ConnectServer("","root\default","","",,,,objCtx)
|
|
Set objReg = objServices.Get("StdRegProv")
|
|
|
|
' Check the hive and give it the right value
|
|
Select Case shive
|
|
Case "HKCR", "HKEY_CLASSES_ROOT"
|
|
hiveKey = &h80000000
|
|
Case "HKCU", "HKEY_CURRENT_USER"
|
|
hiveKey = &H80000001
|
|
Case "HKLM", "HKEY_LOCAL_MACHINE"
|
|
hiveKey = &h80000002
|
|
Case "HKU", "HKEY_USERS"
|
|
hiveKey = &h80000003
|
|
Case "HKCC", "HKEY_CURRENT_CONFIG"
|
|
hiveKey = &h80000005
|
|
Case "HKDD", "HKEY_DYN_DATA" ' Only valid for Windows 95/98
|
|
hiveKey = &h80000006
|
|
Case Else
|
|
MsgBox "Hive not valid (ReadRegistryKey)"
|
|
End Select
|
|
|
|
Set Inparams = objReg.Methods_("GetStringValue").Inparameters
|
|
Inparams.Hdefkey = hiveKey
|
|
Inparams.Ssubkeyname = subkey
|
|
Inparams.Svaluename = valuename
|
|
Set Outparams = objReg.ExecMethod_("GetStringValue", Inparams,,objCtx)
|
|
|
|
ReadRegistryKey = Outparams.SValue
|
|
End Function
|